Proposed Dwelling Elevation

Summary

AI generated summary
Proposed plans and elevations for two new-build semi-detached houses on land adjacent to a council car park in Burley, dated March 2018. The sheet shows front, rear, and side elevations and ground- and first-floor layouts at stated scales. Each home includes an entrance hall, lounge, kitchen/dining area, and a WC/wet room on the ground floor, with three bedrooms and a bathroom on the first floor, plus storage and service locations such as electrical meters and a gas meter box. External finishes and components are specified, including clay roof tiles, red facing brickwork, timber sliding sash windows, high-performance double doors, and powder-coated aluminum ogee gutters and downpipes, with joinery color noted as RAL 9001 (Country Cream). Ecological mitigation measures include bat roosting boxes and swift nesting boxes, with details referenced to a separate report. General notes state the drawing is for planning approval and dimensions must be verified on site.

Document Viewer

GFL FFL CL METERS

1 0 2 3 4 5 6 7 8 9 10

HERITAGE COTTS 2018

METERS @ 1:100

0 1 2 3 4 5 6 7 8

FRONT ELEVATION   REAR ELEVATION   SIDE ELEVATION A   SIDE ELEVATION B

redland rosemary plain

clay tiles. see swatch

micklemersh charnwood

red clay facing bricks. see swatch

howarth timber sliding

sash windows on buff stone

sills with with ig spayed

arch over. see separate

detail

howarth securitherm high

performance double door sets

JOINERY FINISH:

RAL 9001 - COUNTRY CREAM

alumasc heritage

powder-coated

aluminum ogee gutters

& down pipes

bats

bat roosting box's located within external brickwork as high as possible in gable ends. - see eco-mitigation report for full details

bats

sn sn (woodstone) swift nesting boxes located near to eaves. - see eco-mitigation report for full details

FRONT

REAR

ELEVATION A

ELEVATION B

METERS @ 1:50

0 1 2 3 4 5

GROUND FLOOR PLAN

up

D B

M

B

down

BED 2

ENTRANCE

LOUNGE

HALL

KITCHEN

BED 1

BATH

BED 3

DINER

LANDING

AC

WC/

WET ROOM

cpd.

internal electrical meters & DB's secreted at correct height within cupboard

wardrobe wardrobe

wardrobe

SVP

up

D B

M

B

LOUNGE

ENTRANCE

HALL

KITCHEN

DINER

WC/

WET ROOM

cpd.

SVP

down

BED 2

BED 1

BATH

BED 3

LANDING

AC

wardrobe wardrobe

wardrobe

RWP

RWP RWP

RWP

g g

FIRST FLOOR PLAN

ground level gas

meter box's

log burner

Tel/Fax: 01425 472217

3 Wren Close, Hightown, Ringwood, Hants, BH24 3RF

AVON PROJECT SERVICES

REV BY DATE DESCRIPTION

REVISIONS / AMENDMENTS

Original scale size 100mm-this drawing may have been reduced

GENERAL NOTES

scaling for reference only, written dimensions shall govern

copyright APS ltd. all rights reserved. this drawing may not be copied or re-used in whole or in part, without the written consent of APS ltd.

SITE:

CLIENT:

revision:

DWG. TITLE:

PROJECT:

DWG. STATUS:

DWG. No.

date:

Date:

A1 scale:

checked by:

drawn by:

Building Design & Technology

Web: avonserve.com e: info@avonserve.com

@ BURLEY

NFNP AUTHORITY

AS PROPOSED

PROPOSED PLANS & ELEVATIONS

2 NEW-BUILD SEMI-DETACHED DWELLINGS

LAND ADJACENT TO COUNCIL CAR PARK,

MARCH 2018

PA MARCH 2018

P574/12

SA, WL

1:100 & 1:50

////////

//////////

/ // ////////

REDLAND ROSEMARY CLAY CRAFTSMAN

85 ALBURY, SANDED GRANULAR CLAY TILES

MICKLEMERSH CHARNWOOD RED CLAY BRICK

HAMPSHIRE STOCK COBHAM BLEND

  • this drawing is suitable the purposes of obtaining local planning authority approvals only.
  • superstructures shown are indicative and are subject to a structural engineers full feasibility appraisal.
  • all final dimensions are to be determined on site at the setting out stage of the works. discrepancies are likely, and if necessary are to be verified with the client/agent before work proceeds.
  • it is the responsibility of the client and the appointed building contractor to observe all relevant health and safety rules including the construction-design-management (CDM 2015) regulations, as well as any others that may apply such as the party wall act and the construction act

Keep your distance from the animals and don't feed or pet them - you may be fined.

Keep your distance from the animals and don't feed or pet them - you may be fined.

Keep your distance from the animals and don't feed or pet them - you may be fined.

Keep your distance from the animals and don't feed or pet them - you may be fined.