Part G Park Lodge
Summary
AI generated summary
Water efficiency assessment results are provided for two dwellings at the Park Lodge development (Job 5865), assessed on 17/06/2019 by Demi Beneke using the BRE Global basic calculator for new dwellings. Both homes include dual-flush WCs (6L full, 4L part), taps at 6 L/min (excluding kitchen and external), a 190L bath, a 10 L/min shower, and kitchen sink taps at 6 L/min. No washing machine or dishwasher is specified, and there is no waste disposal unit or water softener. The calculated internal water use is 130.9 litres per person per day, with a normalisation factor of 0.91 giving a total consumption of 119.1 litres per person per day. Adding 5.0 litres per person per day for external use gives 124.1 litres per person per day, meeting Building Regulations 17.K compliance.