P574 SAP Notes

Summary

AI generated summary
Specification summary for the Park Lodge dwelling used for SAP/energy compliance. It lists required insulation build-ups and target U-values: ground floor 0.12 (screed, 150mm Celotex XR4000, beam and block), external walls 0.20 (plasterboard, 100mm aircrete block, 75mm Celotex CW4000, 50mm cavity, brick), and ceiling 0.11 (400mm mineral wool). Party walls are to be fully filled with effective edge sealing. Openings include a composite door (U 1.8) and timber-frame double-glazed low-e windows (g 0.71, U 1.4). Ventilation is natural with an air pressure test result of 5 or lower. Heating is a gas Ideal Logic System S24IE with radiators, zoning controls, weather compensation, and a wood burner; changes may affect compliance. Hot water uses a 210L cylinder with controls, insulated pipework, and separate timing. All lighting is low energy, and listed accredited junction details are provided for SAP.

Document Viewer

Accredited S A P / S B E M & Code for Sustainable Homes Assessors – BREEAM - Air Pressure Testing - Smoke Tests – Acoustic Design & Testing - U Value Calculations - Acoustic Specifications – Part G Water Calculations

6 The Saxon Centre, Fountain Way, Christchurch, Dorset, BH23 1QN. Tel: 01202 487463

Email: info@thermalacoustics.co.uk, Web: www.thermalacoustics.co.uk

V.A.T. No. 916 7208 20

Park Lodge

Ground Floor – U-value 0.12

  • 75mm screed
  • 150mm Celotex XR4000
  • Concrete beam and block

External Walls – U-value 0.2

  • 12.5mm plasterboard on dabs
  • 100mm Celcon Solar (lambda 0.11)
  • 75mm Celotex CW4000
  • 50mm cavity
  • 100mm brick outer leaf

Plain Ceiling – U-value 0.11

  • 12.5mm plasterboard
  • Total 400mm mineral wool installed between and over joists

Party walls between dwellings fully filled with effective edge sealing.

Openings

  • Composite wood door u-value 1.8
  • Windows as wood frame, double glazed with low-e soft coat achieving transmittance factor ‘g’ 0.71 and u-value 1.4

Ventilation

  • Natural ventilation
  • Air pressure test of 5 or lower

Heating

  • Allowed gas fired Ideal Logic System S24IE
  • Radiators
  • Time and temperature zone controls
  • Weather compensator
  • Wood log burner

Please note, changing the boiler system may result in a failure. Please contact your SAP assessor to ensure your chosen system will comply in your calculations.

Accredited S A P / S B E M & Code for Sustainable Homes Assessors – BREEAM - Air Pressure Testing - Smoke Tests – Acoustic Design & Testing - U Value Calculations - Acoustic Specifications – Part G Water Calculations

6 The Saxon Centre, Fountain Way, Christchurch, Dorset, BH23 1QN. Tel: 01202 487463

Email: info@thermalacoustics.co.uk, Web: www.thermalacoustics.co.uk

V.A.T. No. 916 7208 20

Water Heating

  • Allowed for 210L hot water cylinder
  • Cylinder in heated space
  • Cylinderstat
  • Fully insulated primary pipework
  • Water heating timed separately

Other

  • 100% low energy light fittings throughout

Junction SAP

Junction SAP Ref. Default Accredited Aircrete Partial Fill
External Wall Junctions
Other Lintels E2 CD0004
Sills E3 MCI-WD-04
Jamb E4 MCI-WD-05
Ground Floor (normal) E5 CD0001
Intermediate Floor within a Dwelling E6 CD0008
Eaves Insulation at Ceiling Level E10 MCI-RE-01
Gable Insulation at Ceiling Level E12 CD0010
Corner (normal) E16 CD0014
Corner (inverted) E17 CD0015
Party Wall Between Dwellings E18 MCI-IW-01 CD0016
Party Wall Junctions
Ground Floor (normal) P1 Yes
Intermediate Floor within a Dwelling P2 Yes
Roof (insulation at ceiling level) P4 Yes