P574 SAP Notes
Summary
AI generated summary
Specification summary for the Park Lodge dwelling used for SAP/energy compliance. It lists required insulation build-ups and target U-values: ground floor 0.12 (screed, 150mm Celotex XR4000, beam and block), external walls 0.20 (plasterboard, 100mm aircrete block, 75mm Celotex CW4000, 50mm cavity, brick), and ceiling 0.11 (400mm mineral wool). Party walls are to be fully filled with effective edge sealing. Openings include a composite door (U 1.8) and timber-frame double-glazed low-e windows (g 0.71, U 1.4). Ventilation is natural with an air pressure test result of 5 or lower. Heating is a gas Ideal Logic System S24IE with radiators, zoning controls, weather compensation, and a wood burner; changes may affect compliance. Hot water uses a 210L cylinder with controls, insulated pipework, and separate timing. All lighting is low energy, and listed accredited junction details are provided for SAP.